IES480K1K 480kW Power Cube
AC grid access | AC input voltage | 45-65Hz / 3-phases + N + PE / 260vac-530vac |
|
AC max input current | 645A | ||
AC Distribution | AC Grid charging power to Energy Storage Battery is max 120kW. to EV is max 240KW |
||
AC feedback power (optional) | Energy Storage Battery max feedback to Grid / B2G is 88KW |
||
Energy Storage | Battery group access channel | Max 2 channels | |
Battery charging power from AC Grid | Max 120KW | ||
Battery access | Battery B2V EV charging power | Max 4 channels | |
Battery B2V EV charging power | Max 240kW | ||
Battery B2G AC grid feedback power (optional) |
Max 88kW | ||
Electric Vehicle | EV Charging point | Max 4 point within 2 Dispensers | |
EV Charging power | Max 480kW | ||
Electric Vehicle Discharging | EV feedback to AC Grid / V2G power (optional) |
Max 176kW | |
EV feedback to Energy Storage Battery /2Bpower (optional) |
Max 120kW | ||
Dimensions | W * H * D mm = 1000 * 2200 * 1200 mm |
IBS215K1KC 200kWH Battery Cube
Energy Storage Battery | 200kWh/280Ah Energy storage battery, Battery voltage: 627V~806V, Charging/ discharging ratio: 0.5 C dis/charge, max 1 C discharge 10 min |
Battery BMS | Battery Pack BSU + High voltage control box master-slave BMU |
Battery Capacity Expand | Max 4 groups battery/battery cube access, 4 BMU |
Fire suppression system | Temperature-activated fire extinguishing system + fire probe tube + Air pressure sensor and valves, emergency fan |
Protection Class | IP65 |
Dimensions/Weight | W * H * D mm = 1200 * 2200 * 1200 / 1600 kg |
EXP480K2-LDC 480kW Charging Dispenser
Normal Charging Cable | CCS1 200A/300A 1000V, CCS2 200A/250A 1000V. CHAdeMO 125A/500V, GBT 250A/1000V |
Liquid cooling cable | 500A/1000V CCS1 or CCS2 or GBT |
Dimensions | W * H * D mm = 500 * 1750 * 350 mm Weight: 160 kg |